
Brand: SMARTEN
Smarten Saver 6000 Pure Sine Wave Solar Inverter 72VDC 50A SCC for Commercial Power Backup Systems
SKU: TI-SS-78437
Estimated Delivery By: Sep 15 - Sep 17 




MRP : ₹90100 ₹64300
29% OFF!
Estimated Delivery By: Sep 15 - Sep 17 
Easy Return
& Refund
& Refund

Quality
Assurance
Assurance

Trusted
Delivery
Delivery

After Sales
Assistance
Assistance

Buyer
Protection
Protection
₹64300 (Including GST)
MRP : ₹90100
29% OFF!
Get Extra ₹965 OFF on Prepaid Orders
QTY :
-
1
+
Short Description
The Smarten Saver 6000 Pure Sine Wave Solar Inverter. It operates on a 6-battery and integrates a high-efficiency Solar Charge Controller (SCC). It is specifically made to handle high startup surge currents, making it ideal for running heavy inductive and resistive commercial loads smoothly during continuous grid outages.
Country of origin: India
Specifications
- Brand: SMARTEN
- Weight (Approx.) : 14 kg
- Model Name : 6000VA
MAINS INPUT MODE :
- Mains AC low cut UPS mode : 175VAC ± 10VAC
- Mains AC low cut recovery UPS mode : 185VAC ± 10VAC
- Mains AC high cut UPS mode : 265VAC ± 10VAC
- Mains AC high cut recovery UPS mode : 255VAC ± 10VAC
- Mains AC low cut WUPS mode : 90VAC ± 10VAC
- Mains AC low cut recovery W.UPS mode : 110VAC ± 10VAC
- Mains AC high cut WUPS mode : 295VAC ± 10VAC
- Mains AC high cut recovery W.UPS mode : 285VAC ± 10VAC
- Input Frequency Range : 40Hz to 60Hz
- Voltage Output in Mains Mode : Same as input
- Frequency Output in Mains Mode : Same as input
BATTERY :
- Battery Type : LA / Tubular / SMF
- DC Input Voltage : 72 V
- Battery Quantity 12V 100Ah to 350Ah : 6
- Float Charging Voltage : 82.2V±0.4V
- Bulk Absorpon Voltage : 88.8V±0.4
- Boost Charging Voltage for LA Battery : 83.5V±0.5V
- Boost Charging Voltage for Tubular and SMF Battery : 86.5V±0.5V
- Battery Deep Discharge Recovery : Yes (Independent Charger to Recover Deep Discharge Battery)
- Charging Current at Grid Priority/Battery Priority : 13A ± 3A
BACKUP MODE :
- Output voltage : 220VAC +5% -10%
- Output frequency : 50Hz ± 0.2 Hz
- Output waveform : Pure Sine Wave ≤ 5% THD
- No Load current : <1.8A
- Discharging current @ full load : 65A ± 2A
- Low Battery Warning : 64.8V±0.5V
- Low Battery Cut : 62.4V±0.5V
- Change over me UPS mode : < 4msec
- Change over me WUPS mode : < 25msec
PROTECTION :
- Phase to Phase Voltage Protecon : Mains Mode
- Back feed protection : Mains apply in output side@<295V
- Over Load system Shutdown : > 130% after approx >180sec, and > 300% system will be shutdown approx < 20 Sec.
- Short Circuit (A PK-PK) : Yes, After 3 tries system will be shutdown (System reset from front switch)
- Reverse Battery : Battery MCB will trip
- SCC Reverse Battery : DC Fuse Burn
- Short Circuit in Mains Mode : Mains MCB Trip
- Battery Over Charge : Yes, Provided
- High PV Voltage : 130V±2V
- Reverse PV Connected : Yes, Provided
- Over Charge Protection : Yes, Provided
- Over Current Protection PV : Yes, Provided
SOLAR CHARGE CONTROLLER :
- Solar Charge Controller type : PWM type
- Max Panel waage can be connected : 4500W
- Max PV current : 50A
- Reverse PV protecon : Yes provided
- Reverse current flow to PV : Yes provided
- Sharing of current when PV and Grid Both are available : If PV power is not sufficient enough to charge the battery, system will start sharing battery charging from PV and grid.
- Option for Grid and Battery priority : Yes, provided, user can set priority for Battery or Grid. Hence user can set system in electricity bill saving.
- DOD definion (Depth of Discharge) : Mains will be connect when battery voltage reach at defined value of the battery voltage.
SOC definion(State of charge : Mains will be connect when battery SOC use defined value of capacity
SOC (State of charge) :
- 20% of battery capacity
- 30% of battery capacity
- 40% of battery capacity
- 50% of battery capacity
Battery Capacity : 100Ah / 150Ah / 200Ah / 250Ah
LCD DISPLAY :
Messages (Display Values can be different 2% from the RMS actual values)
Mains Input Voltage / Battery Voltage / Mains Fuse Blown / Solar Power Available or Not. / Reverse PV / High PV Voltage / Mains Current / Solar Current / Battery Current / PCU ON, OFF / Battery Voltage / Battery Current / Solar Power Available or Not / Load % . / Short Ckt. / Over Load / Wiring Fault / Battery Low. / Battery High / Output Voltage / High Temp. / Output Frequency.
Mains Disconnected, Connected Selecon
If solar is available battery reaches float voltage after <5 min. mains will be disconnected, when mains is connected battery voltage reaches permied DOD voltage and solar power not available.
NOTE: This Condition is not applicable for Grid >> Solar >> Battery Condition.
Description
Power commercial setups, corporate office floors and heavy industrial loads with the Smarten Saver 6000 Pure Sine Wave Solar Inverter. It operates on a 6-battery and integrates a high-efficiency Solar Charge Controller (SCC). It is specifically made to handle high startup surge currents, making it ideal for running heavy inductive and resistive commercial loads smoothly during continuous grid outages. It utilizes daytime solar generation to power running loads directly while simultaneously maintaining the 72V battery bank.
Features
:- Solar-First Energy Priority: Consumes generated solar power first before drawing utility grid power, substantially lowering monthly energy expenses.
- Pure Sine Wave Power Output: Guarantees whisper-quiet motor operation and prevents harmonic distortion or damage in motor loads and sensitive digital devices.
- High-Voltage 72V DC Architecture: Reduces internal current losses and cable heating, ensuring higher efficiency and longer runtime for large commercial setups.
- High-Current 50A Solar Charger: Efficiently handles large solar panel configurations to rapidly recharge the battery bank even in cloudy conditions.
Applications
:- Commercial Offices & Corporate Hubs: Keeps server rooms, computers, lighting networks, and HVAC systems running during grid blackouts.
- Industrial Workshops & Factories: Powers heavy industrial tools, CNC machines, printing presses, and motorized equipment.
- Hospitals & Diagnostic Centers: Delivers ultra-clean sine wave power to critical medical devices, lab equipment, and monitoring tools.
- Educational Campuses & Institutions: Powers administrative blocks, computer labs, and auditorium lighting seamlessly.
AI-generated answers may be inaccurate. Double-check critical facts.
Select attribute








