Short Description
Pilot 2 HP Belt Driven Air Pump
51 mm Double Cylinder
Country of origin: India
Specification
  • Brand: Pilot
  • Max. Pressure : 8 bar
  • Weight (Approx.) : 13 kg
  • Tank Capacity : 3 liters
  • Model No. : PL-2051
  • Power : 2HP
  • Max. Pressure : 8 Bar / 115 PSI
  • Cylinder (mm×piece) : 51 × 2
  • Air Displacement : 170 LPM
  • Type : Belt Driven
Description
The Pilot Oil-Lubricated Air Compressor Head 2051 is engineered for heavy-duty performance, making it an essential tool for professionals in various industries. Known for its reliability and power, this compressor head is designed to meet the demands of rigorous applications.

Features

 :
  • High Performance : With a power rating of 2HP, it delivers consistent air pressure for efficient operation of tools.
  • Max Pressure : Capable of reaching up to 8 Bar/115 PSI, ensuring optimal performance in demanding tasks.
  • Cylinder Efficiency : Designed with a cylinder size of 51x2 mm, maximizing air displacement at an impressive 170L/min.
  • Durability : Crafted with high-quality materials to withstand the rigors of daily use, ensuring long-lasting performance.
  • Smooth Operation : The oil-lubrication system reduces wear and tear, leading to quieter operation and extended lifespan.

Applications

 :
  • Automotive Industry : Perfect for tire inflation, powering pneumatic tools, and servicing equipment, ensuring efficiency in workshops.
  • Construction Sites : Delivers robust air pressure for nail guns and other tools, making it ideal for framing, roofing, and more.
  • Manufacturing and Fabrication : Supports various machinery and processes, enhancing productivity across different manufacturing sectors.

Usage

 :
Usage : 

Safety First
  • Always read and understand the user manual before operation.
  • Wear appropriate safety gear: goggles, gloves, and hearing protection.
  • Use the air pump in a well-ventilated, dry area, away from flammable materials.
  • Ensure all guards (e.g., belt guard) are in place before starting.

Setup
  • Mount the pump securely on a flat, vibration-free surface.
  • Ensure the pump is aligned correctly with the motor using the belt drive.
  • Check oil level in the crankcase (if oil-lubricated) before starting.
  • Verify that all bolts, fittings, and connections are tight and secure.

Starting the Pump
  • Connect the pump to a compatible 2HP electric motor with the correct pulley alignment and belt tension.
  • Turn ON the motor and allow the pump to build pressure gradually.
  • Monitor the pressure gauge if connected to a tank or compressor system.

Operating the Pump
  • Ensure the belt tension is optimal during operation to prevent slippage or wear.
  • Operate the pump within its rated pressure and duty cycle.
  • Avoid continuous operation beyond its designed cycle; allow cooling periods.
  • Use with a compatible air tank and regulator for controlled output pressure.

Shutting Down
  • Turn off the motor powering the pump.
  • Release any residual pressure from the system.
  • Disconnect power if performing maintenance or inspection.

Maintenance :

Daily Maintenance
  • Check oil level and refill if necessary (use compressor-grade oil like SAE 30).
  • Inspect for leaks: air or oil.
  • Listen for unusual noises indicating mechanical wear or looseness.
  • Drain any moisture from the connected air tank.

Weekly Maintenance
  • Clean the air filter: use compressed air to remove dust or replace if heavily soiled.
  • Inspect belt condition: look for cracks, frays, or signs of wear.
  • Check bolt tightness: especially mounting bolts and pulley fasteners.

Monthly Maintenance
  • Inspect pulley alignment and belt tension; adjust if needed.
  • Check oil quality and color: if dark, contaminated, or emulsified, replace it.
  • Examine the intake and exhaust valves for any blockage or buildup.

Oil Change (Every 3 Months or 100 Hours)
  • Warm up the pump for 2–3 minutes to thin the oil.
  • Turn off and unplug the power source.
  • Remove the oil drain plug and drain oil into a container.
  • Refit the plug securely and refill with fresh compressor oil.
  • Avoid overfilling—use the sight glass or dipstick to check the correct level.

Annual Maintenance
  • Deep clean the pump’s cooling fins to ensure proper heat dissipation.
  • Inspect for internal wear, corrosion, or damage (by a technician if needed).
  • Replace worn-out belts, gaskets, or filters.
  • Have a technician perform a full operational test if used regularly in industrial environments.

Storage Tips
  • If not in use for a long time : Drain all oil and moisture, Cover the pump to protect from dust, Store in a dry, cool place away from corrosive materials, Disconnect from the motor or power source.