Brand : Kirloskar
Kirloskar Portable Sentinel Series 3.5 KVA Electric Diesel Start Generator (KG4-P-3.5AS)
SKU : TI-KP-47212
MRP : ₹225999
₹214999
5% OFF!
-
1
+
Get Extra ₹3,225 OFF on Prepaid Orders
Delivery By: Nov 6 - Nov 8
Add to Cart
Buy Now
Easy Return
& Refund
Quality
Assurance
Trusted
Delivery
After Sales
Assistance
Buyer
Protection
Short Description
Kirloskar Portable Sentinel Series 
3.5 KVA Electric Diesel  Start Generator
1.1 Lt/Hr (At 100% Load) /0.93 Lt/Hr (At 75% Load) / 0.78 Lt/Hr (At 50% Load)


Country of origin: India
Specification
  • Brand: Kirloskar
  • Weight (Approx.) : 170 kg
  • Fuel Used : Diesel
  • Fuel Consumption : 1.1 l/hr
General  Specifications:
  • Model No. : KG4-P-3.5AS
  • Rated Output at 230V / 50Hz : 3.5 kW (3.5KVA)
  • Max. Rating (kW/kVA) : 3.5 kW
  • Voltage : 230V
  • Sound Level : < 75dB (A)
  • Fuel Consumption : 1.1 Lt/Hr (At 100% Load) /0.93 Lt/Hr (At 75% Load) / 0.78 Lt/Hr (At 50% Load)
  • Fuel Tank Capacity : 12.5L

Engine :
  • Engine Model : CC 418 G1
  • RPM : 3000
  • Rated Output (Prime Continuous rating) as per ISO 3046 : 5.5KW (7.47 HP)
  • Cubic Capacity : 418cc
  • Lube Oil Change Period : 100 hr.
  • Lube Oil Sump Capacity : 1.65 Lts
  • Starting System : Electric
  • Low Oil Level alert (Trip) : Low Lube Oil Level-No, Low Lube Oil Press-Yes
  • Overload Warning : Yes
  • Battery Charging : Yes
  • Eco Throttle : Mechanical

Inverter :
  • Rated Output at 230V / 50Hz : 3.5 KVA
  • Max Output : 4 KVA
  • % THD (Voltage) : <5%
  • Display Parameters : KG645-Controller (Voltage, Frequency, Hours)
  • Fuel Gauge ( Mech. Level Indicator) : Yes
  • AC Output Connector : Yes
  • AC Circuit Breaker : Yes
  • Overall Dimensions (L x W x H) : 950 X 595 X 855 mm

Description
The KG4-P-3.5AS model from Kirloskar’s Portable Sentinel series is a compact diesel-powered generator set rated at approximately 3.5 kVA (single-phase, 230 V / 50 Hz). It is designed for portable or standby power use where a small-capacity diesel alternative is desirable.

Features

 :
  • Rated capacity : ~3.5 kVA at 230 V/50Hz single phase.
  • Fuel type : Diesel engine (as indicated for “3.5 kVA Diesel Inverter” category)
  • Fuel tank capacity : 12.5 L
  • Consumption : For the 3.5 kVA model: approx. 1.1 Lt/Hr (At 100% Load) /0.93 Lt/Hr (At 75% Load) / 0.78 Lt/Hr (At 50% Load)
  • Voltage output : 230 V single-phase (standard for small portable sets) 
  • Low noise / compact footprint : Spec shows “Sound Level LWA / dB(A) < 75 dB(A)” for this size. 
  • Portable build :  Designed for mobility and practical use in smaller installations or where minimal footprint is needed. Brochures mention “Power on Wheels … mobile power backup … wide length handle … wheels” for this size range. 
  • Output quality : According to the spec sheet, THD (voltage) less than 5% for similar models in the series. 
  • Brand & support : Kirloskar has a wide service network in India, which adds to the appeal from a maintenance & support perspective.

Applications

 :
  • Home backup power : For residences during power outages, to run lighting, fans, TV, smaller refrigerators or other essential appliances.

  • Small business / shop backup : For small retail shops, kiosks, clinics, salons, offices where a few kVA of reliable backup power is required.

  • Outdoor/mobile operations : Such as remote site lighting, field workshops, small events, mobile vendors, small construction jobs that require moderate power.

  • Agricultural/light rural use : In rural areas or farms where grid supply is unstable or absent; for portable pumps, lighting, small motors (within load limits).

  • Because of its size (~3.5 kVA), it is not designed for large industrial motors or three-phase heavy loads, but rather for lighter single-phase loads or standby usage.

Usage

 :
Usage :
  • Install the generator on a level, dry, and well-ventilated outdoor site, ensuring exhaust fumes are away from inhabited spaces and adequate clearance is provided.
  • Before first start (and before every subsequent use):

    Check engine oil level, coolant level (if water-cooled), battery charge (if electric start) and fuel level.
  • Ensure that all cables and loads are disconnected, and that the generator’s control panel is set to standby/ready mode.
  • On starting : 

    Start engine without load, allow it to warm up for a minute or two.
  • Gradually apply load; avoid connecting full load instantly after cold start.
  • Monitor the voltage and frequency; ensure that the load does not exceed the rated capacity (approx. 3.5 kVA) and allow margin for starting surges of motors.
  • During operation : 

    Maintain clean surrounding and ensure ventilation around generator is not obstructed.
  • Monitor fuel consumption, engine temperature, and listen for unusual noises or vibration.
  • If powering sensitive electronics, ensure protection via a UPS or AVR (even though output THD is low) to guard against transients.
  • When shutting down : 

    Remove load first, let the generator run unloaded or lightly loaded for 1–2 minutes to stabilize.
  • Then turn off the generator, allow it to cool, and if storing for longer period, drain fuel if recommended by manufacturer or treat fuel as per guidance.
  • Ensure proper grounding and circuit protection (breaker/fuse) is in place, and wiring is appropriate for the load.

Maintenance :
  • Oil change : According to spec sheet: First oil change after ~20 hours, then every 100 hours (for this portable series) for petrol variants; for diesel variants the period may differ but likely similar interval.

  • Air filter : Regularly inspect the air filter (especially if used in dusty or outdoor environment); clean or replace as required.

  • Fuel system : Use good quality diesel fuel. If the generator is unused for long periods, treat or drain fuel to avoid degradation. Check for leaks or contamination.

  • Battery / electric-start system : Ensure battery remains charged, terminals clean and tight, and that connections are secure.

  • Cooling / ventilation : If air-cooled, ensure fins are clean; if water-cooled, ensure coolant is at proper level and there are no leaks.

  • Exhaust system : Check muffler/silencer and exhaust piping for integrity and appropriate discharge away from operator areas.

  • Load testing : Periodically run the generator under load (not just idle) to ensure all systems function properly, and to prevent stagnation issues.

  • General inspections : Check for loose bolts, vibration, wear and tear, wiring connections, canopy/housing (if enclosed) for corrosion or damage.

  • Record keeping : Maintain a log book of run hours, service dates, oil changes, issues encountered—helps plan preventative maintenance and detect trends.

  • Service network : Use Kirloskar authorized service centers for major maintenance or when engine/alternator parts need replacement to ensure compatibility and support.