Brand: SMARTEN
Smarten 850 Sine Wave Solar Inverter 12VDC 25A SCC for Industrial Power Backup
SKU: TI-S8-78379
Estimated Delivery By: Aug 11 - Aug 13 




MRP : ₹9800 ₹6999
29% OFF!
Estimated Delivery By: Aug 11 - Aug 13 
Easy Return
& Refund
& Refund

Quality
Assurance
Assurance

Trusted
Delivery
Delivery

After Sales
Assistance
Assistance

Buyer
Protection
Protection
₹6999 (Including GST)
MRP : ₹9800
29% OFF!
Get Extra ₹105 OFF on Prepaid Orders
QTY :
-
1
+
Short Description
The Smarten 850 Pure Sine Wave Solar Inverter operates on a single 12V DC battery bank and offers an integrated 25A Solar Charge Controller (SCC). It is built to convert solar power into clean AC electricity, featuring a seamless and sustainable energy backup solution for homes, small commercial shops and light industrial workstations. The Saver 850 automatically runs connected loads using daytime solar generation while simultaneously charging the connected battery.
Country of origin: India
Specifications
- Brand: SMARTEN
- Weight (Approx.) : 12 kg
- Model Name : 850VA
MAINS INPUT MODE :
- Mains AC low cut UPS mode : 175VAC ± 10VAC
- Mains AC low cut recovery UPS mode : 185VAC ± 10VAC
- Mains AC high cut UPS mode : 265VAC ± 10VAC
- Mains AC high cut recovery UPS mode : 255VAC ± 10VAC
- Mains AC low cut WUPS mode : 90VAC ± 10VAC
- Mains AC low cut recovery W.UPS mode : 110VAC ± 10VAC
- Mains AC high cut WUPS mode : 295VAC ± 10VAC
- Mains AC high cut recovery W.UPS mode : 285VAC ± 10VAC
- Input Frequency Range : 40Hz to 60Hz
- Voltage Output in Mains Mode : Same as input
- Frequency Output in Mains Mode : Same as input
BATTERY :
- Battery Type : LA / Tubular / SMF
- DC Input Voltage : 12V
- Battery Quantity 12V 100Ah to 350Ah : 1
- Float Charging Voltage : 13.7V±0.2V
- Bulk Absorpon Voltage : 14.8V±0.2V
- Boost Charging Voltage for LA Battery : 14.0V±0.2V
- Boost Charging Voltage for Tubular and SMF Battery : 14.5V±0.2V
- Battery Deep Discharge Recovery : Yes (Independent Charger to Recover Deep Discharge Battery)
- Charging Current at Grid Priority/Battery Priority : 15A ± 3A
BACKUP MODE :
- Output voltage : 220VAC +5% -10%
- Output frequency : 50Hz ± 0.2 Hz
- Output waveform : Pure Sine Wave ≤ 5% THD
- No Load current : <1.8A
- Discharging current @ full load : 40A ± 2A
- Low Battery Warning : 10.8±0.2V
- Low Battery Cut : 10.4V±0.2V
- Change over time UPS mode : < 10msec
- Change over time WUPS mode : < 25msec
PROTECTION :
- Phase to Phase Voltage Protection : Mains Mode
- Back feed protection : Mains apply in output side@<295V
- Over Load system Shutdown : > 130% after approx >180sec, and > 300% system will be shutdown approx < 20 Sec.
- Short Circuit (A PK-PK) : Yes, After 3 tries system will be shutdown (System reset from front switch)
- Reverse Battery : DC Fuse Burn
- SCC Reverse Battery : DC Fuse Burn
- Short Circuit in Mains Mode : Mains Fuse will blown
- Battery Over Charge : Yes, Provided
- High PV Voltage : 28V± 2V
- Reverse PV Connected : Yes, Provided
- Over Charge Protection : Yes, Provided
- Over Current Protection PV : Yes, Provided
SOLAR CHARGE CONTROLLER :
- Solar Charge Controller type : PWM type
- Max Panel wattage can be connected : 600W
- Max PV current : 25A
- Reverse PV protection : Yes provided
- Reverse current flow to PV : Yes provided
- Sharing of current when PV and Grid Both are available : If PV power is not sufficient enough to charge the battery, system will start sharing battery charging from PV and grid.
- Option for Grid and Battery priority : Yes, provided, user can set priority for Battery or Grid. Hence user can set system in electricity bill saving.
- DOD definion (Depth of Discharge) : Mains will be connect when battery voltage reach at defined value of the battery voltage.
Mains will be connect when battery SOC use defined value of capacity
SOC (State of charge) :
- 20% of battery capacity
- 30% of battery capacity
- 40% of battery capacity
- 50% of battery capacity
Battery Capacity : 100Ah / 150Ah / 200Ah / 250Ah
LCD DISPLAY :
Messages (Display Values can be different 2% from the RMS actual values)
Mains Input Voltage / Battery Voltage / Mains Fuse Blown / Solar Power Available or Not. / Reverse PV / High PV Voltage / Mains Current / Solar Current / Battery Current / PCU ON, OFF / Battery Voltage / Battery Current / Solar Power Available or Not / Load % . / Short Ckt. / Over Load / Wiring Fault / Battery Low. / Battery High / Output Voltage / High Temp. / Output Frequency.
Mains Disconnected, Connected Selecon
If solar is available battery reaches float voltage after <5 min. mains will be disconnected, when mains is connected battery voltage reaches permied DOD voltage and solar power not available.
NOTE: This Condition is not applicable for Grid >> Solar >> Battery Condition.
Description
Power critical lighting, small machinery and essential electronics using the Smarten 850 Pure Sine Wave Solar Inverter. It power system operates on a single 12V DC battery bank and offers an integrated 25A Solar Charge Controller (SCC). It is built to convert solar power into clean AC electricity, featuring a seamless and sustainable energy backup solution for homes, small commercial shops and light industrial workstations. The Saver 850 automatically runs connected loads using daytime solar generation while simultaneously charging the connected battery. Its pure sine wave architecture prevents motor humming and electrical noise, preserving the lifespan of sensitive equipment like laptops.
Features
:- Solar-First Priority System: Maximizes solar energy usage during daylight hours before drawing grid power, dropping recurring utility costs.
- Pure Sine Wave Output: Ensures whisper-quiet motor operation and provides safe power to delicate micro-processor devices.
- Integrated 25A Solar Charger: Efficiently handles solar PV array inputs to charge 12V batteries rapidly even under partial shading.
- Wide AC Input Range: Recharges batteries reliably under severe low-voltage grid conditions without unnecessary battery drain.
Applications
:- Light Industrial Workstations: Powers testing equipment, small bench tools, security cameras, and control panels.
- Residential Homes: Ideal for running LED lighting, ceiling fans, smart TVs, laptops, and Wi-Fi routers during blackouts.
- Retail Outlets & Kiosks: Keeps POS billing machines, LED displays, and credit card terminals online continuously.