Brand: SMARTEN
Smarten 10000 Pure Sine Wave Commercial Solar Inverter 10kVA 120VDC 50A SCC for Commercial Power Backup
SKU: TI-S1-78350
Estimated Delivery By: Aug 11 - Aug 13 




MRP : ₹114800 ₹82000
29% OFF!
Estimated Delivery By: Aug 11 - Aug 13 
Easy Return
& Refund
& Refund

Quality
Assurance
Assurance

Trusted
Delivery
Delivery

After Sales
Assistance
Assistance

Buyer
Protection
Protection
₹82000 (Including GST)
MRP : ₹114800
29% OFF!
Get Extra ₹1,230 OFF on Prepaid Orders
QTY :
-
1
+
Short Description
The Smarten 10000 Pure Sine Wave Solar Inverter operates on a 10-battery 120V DC bank system and integrates an internal 50A Solar Charge Controller (SCC). It is specifically built to handle high startup surge currents, making it ideal for running heavy inductive and resistive loads during continuous power outages. The Saver 10000 uses solar-first energy management to run connected loads directly off solar energy during peak sunlight hours while simultaneously charging the battery bank.
Country of origin: India
Specifications
- Brand: SMARTEN
- Weight (Approx.) : 15 kg
- Model Name : 10000VA
MAINS INPUT MODE :
- Mains AC low cut UPS mode : 175VAC ± 10VAC
- Mains AC low cut recovery UPS mode : 185VAC ± 10VAC
- Mains AC high cut UPS mode : 265VAC ± 10VAC
- Mains AC high cut recovery UPS mode : 255VAC ± 10VAC
- Mains AC low cut WUPS mode : 90VAC ± 10VAC
- Mains AC low cut recovery W.UPS mode : 110VAC ± 10VAC
- Mains AC high cut WUPS mode : 295VAC ± 10VAC
- Mains AC high cut recovery W.UPS mode : 285VAC ± 10VAC
- Input Frequency Range : 40Hz to 60Hz
- Voltage Output in Mains Mode : Same as input
- Frequency Output in Mains Mode : Same as input
BATTERY :
- Battery Type : LA / Tubular / SMF
- DC Input Voltage : 120V
- Battery Quantity 12V 100Ah to 220Ah : 10
- Float Charging Voltage : 137V±0.4V
- Bulk Absorpon Voltage : 148V±0.4V
- Boost Charging Voltage for LA Battery : 139.5V±0.5V
- Boost Charging Voltage for Tubular and SMF Battery : 144.5V±0.5V
- Battery Deep Discharge Recovery : Yes (Independent Charger to Recover Deep Discharge Battery)
- Charging Current at Grid Priority/Battery Priority : 13A ± 3A
BACKUP MODE :
- Output voltage : 220VAC +5% -10%
- Output frequency : 50Hz ± 0.2 Hz
- Output waveform : Pure Sine Wave ≤ 5% THD
- No Load current : <1.8A
- Discharging current @ full load : 66A ± 2A
- Low Battery Warning : 108±0.5V
- Low Battery Cut : 104V±0.5V
- Change over time UPS mode : < 4msec
- Change over time WUPS mode : < 25msec
PROTECTION :
- Phase to Phase Voltage Protection : Mains Mode
- Back feed protection : Mains apply in output side@<295V
- Over Load system Shutdown : > 130% aer approx >180sec, and > 300% system will be shutdown approx < 20 Sec.
- Short Circuit (A PK-PK) : Yes, Aer 3 tries system will be shutdown (System reset from front switch)
- Reverse Battery : Battery MCB will trip
- SCC Reverse Battery : DC Fuse Burn
- Short Circuit in Mains Mode : Mains MCB Trip
- Battery Over Charge : Yes, Provided
- High PV Voltage : 55V ± 2V
- Reverse PV Connected : Yes, Provided
- Over Charge Protection : Yes, Provided
- Over Current Protection PV : Yes, Provided
SOLAR CHARGE CONTROLLER :
- Solar Charge Controller type : PWM type
- Max Panel wattage can be connected : 8000W
- Max PV current : 50A
- Reverse PV protection : Yes provided
- Reverse current flow to PV : Yes provided
- Sharing of current when PV and Grid Both are available : If PV power is not sufficient enough to charge the battery, system will start sharing battery charging from PV and grid.
- Option for Grid and Battery priority : Yes, provided, user can set priority for Battery or Grid. Hence user can set system in electricity bill saving.
- DOD definion (Depth of Discharge) : Mains will be connect when battery voltage reach at defined value of the battery voltage.
LCD DISPLAY :
Messages (Display Values can be different 2% from the RMS actual values)
Mains Input Voltage / Battery Voltage / Mains Fuse Blown / Solar Power Available or Not. / Reverse PV / High PV Voltage /
Mains Current / Solar Current / Battery Current / PCU ON, OFF / Battery Voltage / Battery Current / Solar Power Available or
Not / Load % . / Short Ckt. / Over Load / Wiring Fault / Battery Low. / Battery High / Output Voltage / High Temp. / Output Frequency.
Mains Disconnected, Connected Selecon
If solar is available battery reaches float voltage after <5 min. mains will be disconnected,
when mains is connected battery voltage reaches permied DOD voltage and solar power not available.
NOTE: This Condition is not applicable for Grid >> Solar >> Battery Condition.
Description
Power industrial machinery, entire office floors and heavy commercial loads with the Smarten 10000 Pure Sine Wave Solar Inverter. This power conditioning unit operates on a 10-battery 120V DC bank system and integrates an internal 50A Solar Charge Controller (SCC). It is specifically built to handle high startup surge currents, making it ideal for running heavy inductive and resistive loads during continuous power outages. The Saver 10000 uses solar-first energy management to run connected loads directly off solar energy during peak sunlight hours while simultaneously charging the battery bank. Attached with advanced pure sine wave output technology, it enables zero electrical noise or harmonic distortion, extending the lifespan of sensitive micro-processor equipment.
Features
:Commercial Solar-First Priority: Maximizes solar energy consumption for connected loads and minimizes grid draw to significantly lower monthly energy overheads.
Pure Sine Wave Output: Eliminates electrical noise and humming sounds, ensuring smooth, safe operation for air conditioners, motors, and sensitive electronics.
High-Voltage 120V DC Battery Architecture: Reduces internal current losses and cable heating for high system efficiency and longer backup runtimes.
Integrated 50A Solar Charger: Efficiently handles large solar panel configurations to rapidly recharge the battery bank even in cloudy conditions.
Applications
:- Commercial Offices & Corporate Hubs: Keeps server rooms, computers, lighting networks, and HVAC systems running during grid blackouts.
- Industrial Workshops & Factories: Powers heavy industrial tools, CNC machines, printing presses, and motorized equipment.
- Hospitals & Diagnostic Centers: Delivers ultra-clean sine wave power to critical medical devices, lab equipment, and monitoring tools.
- Educational Campuses & Institutions: Powers administrative blocks, computer labs, and auditorium lighting seamlessly.
AI-generated answers may be inaccurate. Double-check critical facts.