Smarten Saver 2650 Pure Sine Wave Solar Inverter 24VDC 50A SCC for Home and Office Power Backup Systems

813 people have viewed this recently
Estimated Delivery By: Sep 24 - Sep 26 
& Refund

Assurance

Delivery

Assistance

Protection
Short Description
Specifications
- Brand: SMARTEN
- Weight (Approx.) : 14 kg
- Model Name : 2650VA
- Mains AC low cut UPS mode : 175VAC ± 10VAC
- Mains AC low cut recovery UPS mode : 185VAC ± 10VAC
- Mains AC high cut UPS mode : 265VAC ± 10VAC
- Mains AC high cut recovery UPS mode : 255VAC ± 10VAC
- Mains AC low cut WUPS mode : 90VAC ± 10VAC
- Mains AC low cut recovery W.UPS mode : 110VAC ± 10VAC
- Mains AC high cut WUPS mode : 295VAC ± 10VAC
- Mains AC high cut recovery W.UPS mode : 285VAC ± 10VAC
- Input Frequency Range : 40Hz to 60Hz
- Voltage Output in Mains Mode : Same as input
- Frequency Output in Mains Mode : Same as input
- Battery Type : LA / Tubular / SMF
- DC Input Voltage : 24V
- Battery Quantity 12V 100Ah to 350Ah : 2
- Float Charging Voltage : 27.4V± 0.2V
- Boost Charging Voltage for LA Battery : 28.0V±0.3V
- Boost Charging Voltage for Tubular and SMF Battery : 29.0V±0.2V
- Battery Deep Discharge Recovery : Yes (Independent Charger to Recover Deep Discharge Battery)
- Charging Current at Grid Priority/Battery Priority : 15A ± 3A
- Output voltage : 220VAC +5% -10%
- Output frequency : 50Hz ± 0.2 Hz
- Output waveform : Pure Sine Wave ≤ 5% THD
- No Load current : <1.8A
- Discharging current @ full load : 70 ±2A
- Low Battery Warning : 21.4V ± 0.2V
- Low Battery Cut : 21V ± 0.2V
- Change over time UPS mode : < 10msec
- Change over time WUPS mode : < 25msec
- Phase to Phase Voltage Protection : Mains Mode
- Back feed protection : Mains apply in output side@<295V
- Over Load system Shutdown : > 130% after approx >180sec, and > 300% system will be shutdown approx < 20 Sec.
- Short Circuit (A PK-PK) : Yes, After 3 tries system will be shutdown (System reset from front switch)
- Reverse Battery : DC Fuse Burn
- SCC Reverse Battery : DC Fuse Burn
- Short Circuit in Mains Mode : Mains MCB Trip
- Battery Over Charge : Yes, Provided
- High PV Voltage : 55V±2V
- Reverse PV Connected : Yes, Provided
- Over Charge Protection : Yes, Provided
- Over Current Protection PV : Yes, Provided
- Solar Charge Controller type : PWM type
- Max Panel wattage can be connected : 1800W
- Max PV current : 50A
- Reverse PV protection : Yes provided
- Reverse current flow to PV : Yes provided
- Sharing of current when PV and Grid Both are available : If PV power is not sufficient enough to charge the battery, system will start sharing battery charging from PV and grid.
- Option for Grid and Battery priority : Yes, provided, user can set priority for Battery or Grid. Hence user can set system in electricity bill saving.
- DOD definion (Depth of Discharge) : Mains will be connect when battery voltage reach at defined value of the battery voltage.
- 20% - if battery voltage is : 25.0v±0.2V
- 30% - if battery voltage is : 24.0v±0.2V
- 40% - if battery voltage is : 23.0v±0.2V
- 50% - if battery voltage is : 22.0v±0.2V
- 20% of battery capacity
- 30% of battery capacity
- 40% of battery capacity
- 50% of battery capacity
- Solar>>Grid>>Battery
- Solar>>Battery>>Grid
Description
Features
:Solar-First Energy Priority: Consumes generated solar energy first before drawing grid electricity, substantially lowering monthly utility bills.
Pure Sine Wave Electricity: Guarantees quiet, cool motor operation and prevents harm to sensitive digital equipment.
High-Current 50A Solar Charger: Fast-charges 24V battery banks even on partially overcast days using up to 50A solar input current.
Wide Input Voltage Range: Charges batteries reliably during severe low-voltage grid fluctuations without unnecessary battery drain.
Applications
:Residential Homes & Villas: Ideal for running refrigerators, washing machines, lights, ceiling fans, smart TVs, laptops, and Wi-Fi routers.
Small & Medium Offices: Powers multiple desktop computers, billing machines, security cameras, printers, and network servers uninterrupted.
Retail Outlets & Commercial Clinics: Keeps critical diagnostic devices, POS terminals, and indoor lighting functional 24/7.
AI-generated answers may be inaccurate. Double-check critical facts.